img

Products

VAF

The VAF model meters from Trinity are True RMS type digital meters for use in three phase four wire LT electrical systems. The design of these meters is based on proven micro-controller technology, resulting in compact and accurate meters. The design uses powerful micro-controller based technology. The meter uses state of the art Digital Signal Processing (DSP) circuitry to achieve very high accuracy measurement of True RMS value of all parameters. The meter displays the readings on Crisp Super bright LED Displays.

Features

  • Class 1.0 accuracy
  • Compact 96 x 96 x 55 mm DIN enclosure
  • Ideal for supervision & audit of specific loads
  • Micro-Controller based
  • True RMS

Parameters Displayed

  • V, A, Hz.

Specifications

Sr. No. Parameters & Options Statistics
1. Volts R-N Direct Voltage Input : Up to 300V L-N
Burden : 0.5VA
Secondary Voltage Input : 63.5V*
2. Volts Y-N
3. Volts B-N
4. Volts RY Direct Voltage Input : Up to 500V L-L
Burden : 0.5VA
Secondary Voltage Input : 110V*
5. Volts YB
6. Volts BR
7. Current R Secondary Current Input : 5A or 1A (To be specified at thetime of Ordering)
CT- Primary : Site Selectable
Range of Reading : 5 – 5000A
Burden : < 1.0VA
Overload(Through CT) : 5A CT = 6A RMS Continuous
1A CT = 1.2A RMS Continuous
(Whole Current) : 120% of Imax continuous.
8. Current Y
9. Current B
10. Frequency 45 to 55 Hz, Accuracy : 0.3% of Reading
11. DISPLAY 0.4” Red Seven Segment.
12. Installation (a) 3P4W and 1P2W(b) 3P3W (optional)
13 Weight 0.3 kg (approx.)
14 Bezel 96x96 mm DIN enclosure
15 Depth 55 mm
1 Volts R-N Direct Voltage Input : Up to 300V L-N
Burden : 0.5VA
Secondary Voltage Input : 63.5V*
2 Volts Y-N Direct Voltage Input : Up to 300V L-N
Burden : 0.5VA
Secondary Voltage Input : 63.5V*
3 Volts B-N Direct Voltage Input : Up to 300V L-N
Burden : 0.5VA
Secondary Voltage Input : 63.5V*
4 Volts RY Direct Voltage Input : Up to 500V L-L
Burden : 0.5VA
Secondary Voltage Input : 110V*
5 Volts YB Direct Voltage Input : Up to 500V L-L
Burden : 0.5VA
Secondary Voltage Input : 110V*
6 Volts BR Direct Voltage Input : Up to 500V L-L
Burden : 0.5VA
Secondary Voltage Input : 110V*
7 Current R Direct Voltage Input : Up to 500V L-L
Burden : 0.5VA
Secondary Voltage Input : 110V*
8 Current Y Direct Voltage Input : Up to 500V L-L
Burden : 0.5VA
Secondary Voltage Input : 110V*
9 Current B Secondary Current Input : 5A or 1A (To be specified at thetime of Ordering)
CT- Primary : Site Selectable
Range of Reading : 5 – 5000A
Burden : < 1.0VA
Overload(Through CT) : 5A CT = 6A RMS Continuous
1A CT = 1.2A RMS Continuous
(Whole Current) : 120% of Imax continuous.
10 Frequency 45 to 55 Hz, Accuracy : 0.3% of Reading
11 DISPLAY 0.4” Red Seven Segment.
12 Installation (a) 3P4W and 1P2W(b) 3P3W (optional)
13 Weight 0.3 kg (approx.)
14 Bezel 96x96 mm (DIN enclosure)
15 Depth 55 mm (DIN enclosure)