The most versatile and intelligent Multifunction meter for measuring all the basic electrical parameters along with energy and power.
| Sr. No. | Parameters & Options |
|
|
|---|---|---|---|
| 01 | Volts R-N | Direct Voltage Input : Up to 300V L-N Burden : 0.5VA Secondary Voltage Input : 63.5V* |
|
| 02 | Volts Y-N | ||
| 03 | Volts B-N | ||
| 04 | Volts RY | Direct Voltage Input : Up to 500V L-L Burden : 0.5VA Secondary Voltage Input : 110V* |
|
| 05 | Volts YB | ||
| 06 | Volts BR | ||
| 07 | Current R | Secondary Current Input : 5A or 1A (To be specified at thetime of Ordering) CT Primary : Site Selectable Range of Reading : 0 – 4000A Burden : < 1.0VA Overload(Through CT) : 5A CT = 6A RMS Continuous 1A CT = 1.2A RMS Continuous (Whole Current) : 120% of Imax continuous. |
|
| 08 | Current Y | ||
| 09 | Current B | ||
| 10 | Frequency | 45 to 55 Hz, Accuracy : 0.3% of Reading | |
| 11 | KWh | Range of Reading : 0 to 9999999.9 KWh Accuracy : 1.0S as per IS13779. |
|
| 12 | KVARh | Range of Reading : 0 to 9999999.9 KWh Accuracy : 1.5% of Reading (Between 0.5 Lag to 0.8 Lead) |
|
| 13 | KVAh | Range of Reading : 0 to 9999999.9 KWh Accuracy : 1.0% of Reading |
|
| 14 | System PF | Accuracy : 1% of Reading (IPFI>0.5) Range of Reading : 0.05 to 1.00 Lag/Lead |
|
| 15 | System KVA | Accuracy : 1.0% of Reading | |
| 16 | System KW | Accuracy : 1.0% of Reading (Between 0.5 Lag to 0.8 Lead) |
|
| 17 | System KVAR | Accuracy : 1.5% of Reading (Between 0.5 Lag to 0.8 Lead) |
|
| 18 | DISPLAY | 0.4” Red Seven Segment. | |
| 19 | RS485 | For Integration with EMS/SCADA | |
| 20 | Bezel | 96x96 mm | DIN enclosure |
| 21 | Depth | 55 mm | |
| 1 | Volts R-N | Direct Voltage Input : Up to 300V L-N Burden : 0.5VA Secondary Voltage Input : 63.5V* |
| 2 | Volts Y-N | Direct Voltage Input : Up to 300V L-N Burden : 0.5VA Secondary Voltage Input : 63.5V* |
| 3 | Volts B-N | Direct Voltage Input : Up to 300V L-N Burden : 0.5VA Secondary Voltage Input : 63.5V* |
| 4 | Volts RY | Direct Voltage Input : Up to 500V L-L Burden : 0.5VA Secondary Voltage Input : 110V* |
| 5 | Volts YB | Direct Voltage Input : Up to 500V L-L Burden : 0.5VA Secondary Voltage Input : 110V* |
| 6 | Volts BR | Direct Voltage Input : Up to 500V L-L Burden : 0.5VA Secondary Voltage Input : 110V* |
| 7 | Current R | Secondary Current Input : 5A or 1A (To be specified at thetime of Ordering) CT Primary : Site Selectable Range of Reading : 0 – 4000A Burden : < 1.0VA Overload(Through CT) : 5A CT = 6A RMS Continuous 1A CT = 1.2A RMS Continuous (Whole Current) : 120% of Imax continuous |
| 8 | Current Y | Secondary Current Input : 5A or 1A (To be specified at thetime of Ordering) CT Primary : Site Selectable Range of Reading : 0 – 4000A Burden : < 1.0VA Overload(Through CT) : 5A CT = 6A RMS Continuous 1A CT = 1.2A RMS Continuous (Whole Current) : 120% of Imax continuous |
| 9 | Current B | Secondary Current Input : 5A or 1A (To be specified at thetime of Ordering) CT Primary : Site Selectable Range of Reading : 0 – 4000A Burden : < 1.0VA Overload(Through CT) : 5A CT = 6A RMS Continuous 1A CT = 1.2A RMS Continuous (Whole Current) : 120% of Imax continuous |
| 10 | Frequency | 45 to 55 Hz, Accuracy : 0.3% of Reading |
| 11 | KWh | Range of Reading : 0 to 9999999.9 KWh Accuracy : 1.0S as per IS13779 |
| 12 | KVARh | Range of Reading : 0 to 9999999.9 KWh Accuracy : 1.5% of Reading (Between 0.5 Lag to 0.8 Lead) |
| 13 | KVAh | Range of Reading : 0 to 9999999.9 KWh Accuracy : 1.0% of Reading |
| 14 | System PF | Accuracy : 1% of Reading (IPFI>0.5) Range of Reading : 0.05 to 1.00 Lag/Lead |
| 15 | System KVA | Accuracy : 1.0% of Reading |
| 16 | System KW | Accuracy : 1.0% of Reading (Between 0.5 Lag to 0.8 Lead) |
| 17 | System KVAR | Accuracy : 1.5% of Reading (Between 0.5 Lag to 0.8 Lead) |
| 18 | Display | 0.4” Red Seven Segment |
| 19 | RS485 | For Integration with EMS/SCADA |
| 20 | Bezel | 96x96 mm ( DIN enclosure ) |
| 21 | Depth | 55 mm ( DIN enclosure ) |